Wrapping the pipe in my opinion is.
Plastic soil pipe in concrete floor. I want to cover up the soil with cement to flush the floor. The other contractor says no way no plastic holds the water in the concrete during the drying process and can leave webbing like visual affect in finish of concrete. You may be able to carefully chip the cement in the collar of the clay pipe away and remove that plastic section you should then find a pan connector will fit snugly and watertight into the clay pipe to accept the outlet from the new pan. The pvc pipe is the thin type.
This will create a drainage layer and a supportive structure for your concrete. I was thinking of using a concrete mix. Soil pipe under concrete floor i m building a ground floor under stairs toilet. One contractor says to put plastic under the concrete it prevents moisture from coming up into the concrete.
I live in an all year warm climate btw. Running plastic water pipe through concrete floor. Personaly i would sleeve all pipework through a concrete floor the more protection the better you don t want to go to the expense of laying your new floor then find a problem a few years down the line. That means you can have one continuous run with no joints and the plastic pipe should last indefinitely.
If it ever does need replacing you will probably only have to dig out at either end and feed new pipe into the conduit. Answered 27th may 2017. Pour a 2 inch thick layer of gravel over the base of the trench. I don t know what the current building regulations require.
If the copper pipes are installed directly into the soil the soil itself can cause corrosion especially if the soil contains a lot of sulfide or chloride. My advice is to avoid running copper pipes in concrete if possible. Long story short pvc is fine under concrete. Is it ok to pour the concrete.
I replaced the damaged section with schedule 40. While copper is a safe material to use for potable water pipes once the pipes start to corrode it can affect the quality of the water. Spread the gravel evenly using a spade or rake. Make good around the new pan connector with mortar to level it off if desired.
My area has made illegal all metallic pipes in any new construction application so plastics are the only choice. Clean the pipe to remove dirt and debris that could reduce the effectiveness of the concrete to pvc seal. I ve dug up the concrete floor and laid a 4 metre 110mm brown soil pipe that runs to the back of the house and down to the main drain.